2-Zone Thermal Shock Test Chamber

2-Zone Thermal Shock Test Chamber

 

INTRODUCTION

2TS hot cold thermal shock test chamber is available in small capacity and large capacity to meet different testing requirements. The specimen automatic transferred from cold chamber to hot chamber by basket. The basket slides vertically and smoothly through rails, to make the specimen is exposed to the two chambers. Thermal shock test chamber has upgraded to touch-screen controller with Ethernet, you are easy to operate over network.

MODEL

 
Model TS-162 TS-340 TS-500 TS-1000
Inner dimensions of test room (mm) 300*300*250 450*450*360 650*650*500 850*850*700
Volume of test room (mm) 22L 72L 211L 505L
Load of test room 20kg 30kg 50kg 60kg
Overall dimensions(mm) 1560*870*1545 1710*1020*1845 1910*1220*2265 2110*1420*2665

Pre-heat room

 

Upper limit preheat temperature +220℃
Heating time Ambient temperature to ~ + 200℃, within in 30 minutes.

 

Pre-cool room

Lower limit pre-cool temperature -75℃
Cooling time Ambient temperature to ~ -70℃, within in 30 minutes
Test room High temperature  exposure  range Ambient temperature +20 to +200°C
Low temperature exposure range –65 to -5°C
Recovery time Within 15 minutes
Temperature fluctuation ≤±0.5℃
Temperature deviation ≤±3 ℃
Controller Programmable color LCD touch screen controller
Cooling system Mechanical compression refrigeration system
Safety device Over-temperature protection; over-current protection; refrigerant high-pressure protection; earth leakage protection
Exterior material Steel Plate with protective coating
Interior material SUS304 stainless steel
Power Supply 380V 50HZ
Environmental conditional 5℃~+40 ℃   ≤85% RH
 
 