NPI PSA Integrated Nitrogen Generator
  • PSA pressure swing adsorption technology
  • Purity and flow rate adjustable as required
  • Highly integrated, low-noise operation
  • Intelligent multi-unit and integrated design
  • Compact size, easy to move

Application

Compressor, dryer and PSA generator in one unit: nitrogen for laboratories, single machines such as selective soldering, and small production lines. 4 sizes, up to 150 L/min.

Nitrogen output (L/min)

Output (L/min) NPI05 NPI35 NPI70 NPI120
97% 8 40 90 150
99% 5 35 70 120
99.5% 4 30 60 100
99.9% 3 25 50 80
99.99% 2 20 30 50
99.999% 1 15 20 30

Technical data

Parameter NPI05 NPI35 NPI70 NPI120
Weight 35 kg 140 kg 270 kg 320 kg
Power 0.4 kW 1.5 kW 2.3 kW 3.8 kW
Size L × W × H, mm 380 × 500 × 450 600 × 860 × 760 850 × 1000 × 1200 1050 × 1000 × 1200
Dew point < -20 °C < -40 °C < -40 °C < -40 °C
N2 interface G1/8 Ø8 Ø8 Ø8
Voltage 1-phase 220 V 1-phase 220 V 3-phase 380 V 3-phase 380 V
Parameter Value
Pressure 6 bar
Noise < 60 dB
Ambient temperature 5 °C to 40 °C
Method PSA (pressure swing adsorption)
Air compressor Built-in

Reference working conditions: ambient temperature 20 °C; measuring altitude 0 m; outlet nitrogen to ISO 8573-1:2010 class 1-2-1; sizes L × W × H.